Model No: KNLE1-100
Marka: Korlen
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: Elcb
Poles Number: 2
Type: Circuit Breaker
Function: Conventional Circuit Breaker
Certification: Ce
Rated Worling Current: 63;80;100a
Frame: 100a
Maximum Operating Time: I△n T≤0.1s , 5i△n T≤0.04
Sensibility: Ac Type
Rated Working Voltage: 240/415v
Packaging: karton
wydajność: 5000000PCS/Year
transport: Ocean,Land,Air
Place of Pochodzenia: Wenzhou; Zhejiang; Chiny
Certyfikat: CE,CB;VDE;
Código HS: 8536200000
Porta: Ningbo,ShangHai
Rodzaj płatności: L/C,T/T,D/P,Paypal
RCBO to resztkowy wyłącznik prądu z ochroną nadprądową. Zasadniczo wykonuje razem funkcje MCB i RCCB. Oznacza to, że można ją użyć do ochrony linii przed przeciążeniem i zwarciem, a także rzadkiej zmiany linii w normalnej sytuacji.
Wyłącznik szczelności serii KNLE1-100 nakłada się na linii do 230 V dla pojedynczej fazy lub do 400 V dla trzech faz z znamionowym prądem do 63A, aby działać jako ochrona przed wyciekiem. Tam, gdzie ktoś otrzymuje porażenie elektryczne lub prąd wycieku na linii, przekracza określoną wartość, wyłącznik może automatycznie przełamać moc w 0,2S, aby chronić korpus i sprzęt.
Wyłącznik szczelności serii KNLE1-100 wykonuje ochronę przeciążenia i zwarcia, a także wykonuje niską częstotliwość przełączania obwodu w normalnym stanie. Ten produkt jest zgodny z wymogiem standardów GB16917.1.
Wyłącznik prądu upływowego
Wyłącznik wycieków
ELCB
Frame class | 100A |
Rated working voltage | 240/415V |
Rated frequency | 50/60Hz |
Rated working current | 63,80,100A |
Rated residual operating current | 0.03,0.1A |
Rated residual un-operating current | 0.015,0.05A |
Sensibility | AC Type |
Maximum operating time | IΔn t≤0.1s , 5IΔn t≤0.04 |
Instant release type | C type |
Limiting value of un-operating current | 6In |
Rated limiting short-circuit current | 6000A |
Pole number | 1P+N,2P,3P,3P+N |
Mechanical life | 8000 |
Electric life | 4000 |
Sequence NO . |
Release |
Test current I/In |
Start state |
Tripping time |
Expected restlt |
1 | c | 1.13In | Cold state | t≤2h | Not tripping |
2 | c | 1.45In |
Start right after the serial NO . 1 test |
t<2h | Tripping |
3 | c | 2.55In | Cold state | 1s<t<120s | Tripping |
4 | c | 5In | Cold state | t≤0.1s | Not tripping |
5 | c | 10In | Cold state | t<0.1s | Trippi |